Expert bio-decontamination validation services from Protak Scientific – manufacturers of Enzyme Indicators
In addition to Enzyme Indicator technology, we provide expert consultancy services for organisations requiring bio-decontamination validation of facilities, equipment and processes – offering validation lifecycle support for a range of unique needs and requirements.
Protak offers comprehensive technical support. We’ll produce a user requirements specification (URS) that covers all of the technical and functional aspects of your product or process and we’ll make sure that your URS matches your requirements. Sometimes, things change and there may be a need to provide a specialised unique solution.
An effective URS would include:
- Your objectives
- Detailed technical specifications
- Design data
- Validation process documentation
- Installation, operational and performance qualification
- Training details
Protak provides the technical support enabling your full User Requirements Specification to be drafted and approved before the review to establish whether the requirements match the specification or if there may be a need to provide a specialised bespoke solution.
Our subject matter experts deliver a unique mapping procedure identifying and prioritising your requirements before preparing user requirements for review.
End to End Validation Lifecycle Testing
Our technical team are able to assist with your validation lifecycle testing process. We’ll deliver the necessary equipment documentation while providing support through validation development and continuation in use
End to end (E2E) is a testing methodology that is used to ensure the asset behaves as it is intended to do so. It involves testing the workflow from beginning to end.
Validation lifecycle is an approach towards the product that identifies elements at the concept stage through to customer end- use. It also involves a continuous feedback loop which confirms the product’s adherence from the original specification through to customer requirements. Adherence is ensuring the product or service meets and maintains regulatory compliance.
Planning and Design phase – Validation Documentation
Before introducing our advanced Enzyme Indicator validation tool into your bio-decontamination processes we’ll provide a detailed assessment to determine how we effectively deliver your business requirements – and those of your customers. This documentation will include the verification, validation and design activities that are required.
Functional Design Specification
We provide Functional Design Specifications (FDS) to ensure your project is clearly defined and includes requirements for standards, associated documentation and regulatory requirements as well as detail of any control involved. A completed FDS ensures that all departments are aware of what is to be delivered at the end of the project.
Load Optimisation
A gaseous decontaminant, such as Hydrogen Peroxide (H2O2), acts as a surface decontaminant and will not penetrate any occluded surfaces to achieve effective decontamination which is why our Enzyme Indicators offer significant advantages over traditional methods.
Our Enzyme Indicators provide 100% performance assurance and quantifiable results to ensure optimisation of cycle design for multiple surface types and challenge points simultaneously.
Enzyme Indicators reduce risk of routine cycle failures, eliminating false positives and providing safer bio-decontamination.
We’ll advise on how enclosures and chambers should be set up to ensure adequate distribution and space to allow surface contact decontamination and prevent any spaces where H2O2 cannot contact.
The impact of the decontamination cycle is analysed by several factors such as surface area of the items within the load configuration and its compatibility and permeability of H2O2 on the material used.
Our technical team will advise on the setting of loading configurations to ensure efficacy is reached and consistent results are obtained. If required, a cycle load configuration can be optimised to ensure effective decontamination is reached.
Design Qualification
We’ll manage your required Design Qualification (DQ) to ensure verification that your proposed facility or equipment design is suitable for its intended purpose. This often includes vendor documentation such as user and operational manuals, which can aid the verification.
Installation Qualification
Installation Qualification (IQ) verifies the asset has been properly delivered, installed and configured according to the manufacturer’s specification. IQ also checks for energy supply and environmental conditions are acceptable as well as verifying the documentation received and software included.
Operational Qualification
Operational Qualification (OQ) involves testing the installed asset and making sure it performs as intended within its operational ranges and as listed by the manufacturer. All aspects of the asset are tested and appropriate documentation notes the operations and parameters tested for quality assurance.
Performance Qualification
Performance Qualification (PQ) aims to prove that the asset is working within its accepted range and consistently performs under real-time conditions. The asset will be tested against a detailed test plan and aims to generate reproducible results every single time.
Project Troubleshooting
Our technical team can aid in the investigation of bio-decontamination challenges such as Biological Indicator failures, long cycle durations or load configuration set-up.
From as little as one Enzyme Indicator distribution cycle we can carry out contamination control analysis to aid in investigations and visualising potential causes of a problem.
Once identified, our team will provide a technical report summary of findings for review and assist i n setting Corrective Actions and Preventative Actions (CAPA).
We’re able to review technical risk assessments and provide feedback on areas to improve to ensure full coverage of the risks outlined.
We use Failure Mode and Effects Analysis (FMEA) to prioritise potential defects based on their severity and impact. We map out your process from start to finish with the impact, frequency and detectability scored, based on historical data provided on the facility and equipment.
An FMEA can be performed on an existing facility where the data is verified and also is beneficial to a new process in order to identify the gaps and improvements. Recommendations can also be made based on those identified.
Staff Training
Protak can arrange staff training to aid with your new facility or equipment installation.
Ensuring lasting and efficient system operation requires a solid starting knowledge base. Through practical exercises, in-person training and e-learning options, we equip you with the skills you need to run and maintain your system at optimal levels. Our technical team also supports you as needed after you have finished your training.
Arrange a presentation
To find out more, just get in contact with us to arrange a presentation from a member of our team. They’ll get to know your organisation and its goals before highlighting how we can support your business validation processes.